GCSE Physics (9-1)

7.3 Induced potential, transformers and the national grid — Practise with help

Work each problem first. Open a hint only if you are stuck, and the full working only to check.

Warm-up: remember

Answer these from memory. They use ideas from Sections 7.2 and 6.4.

  1. State the three factors that affect the size of the force on a current-carrying conductor in a magnetic field.
  2. A power supply has a potential difference of 12 V and drives a current of 2.0 A. Calculate the power.
Answers
  1. The size of the current, the magnetic flux density, and the length of the conductor in the field.
  2. P=VI=12×2.0=24 WP = VI = 12 \times 2.0 = 24\,\text{W}.

If question 1 went wrong, look again at the motor effect in Section 7.2. If question 2 went wrong, look at electrical power in Section 6.4.

Practise with help

1. Describe the generator effect.

Hint

The effect needs a change: either the conductor moves, or the field changes.

Next step

Say what is induced across the ends of the conductor, and what happens if the conductor is in a complete circuit.

Full working

If an electrical conductor moves relative to a magnetic field, or the magnetic field around it changes, a potential difference is induced across its ends. If the conductor is part of a complete circuit, the induced potential difference drives a current. The induced current makes a magnetic field that opposes the original change. This is a model answer for you to compare with your own wording.

2. State two ways to increase the size of an induced potential difference, and one way to reverse its direction.

Hint

Think about how fast the change happens, and how strong the field is.

Next step

Name a change to the movement and a change to the field for the size. For the direction, name a change that turns the effect around.

Full working

To increase the size: move the conductor faster through the field, or use a stronger magnetic field, or use a coil with more turns. To reverse the direction: reverse the direction of movement, or reverse the direction of the magnetic field.

3. Explain how the generator effect is used in an alternator to generate a.c., and in a dynamo to generate d.c.

Hint

The difference is what happens to the connections as the coil turns.

Next step

Say that the coil rotates in a field in both cases. Then say what the alternator does to the current each half turn, and what the commutator does in a dynamo.

Full working

In both machines a coil rotates in a magnetic field, so a changing field passes through the coil and a potential difference is induced.

In an alternator, the connections stay the same, so the current in the outside circuit reverses every half turn. The output is alternating current.

In a dynamo, a commutator reverses the connections every half turn, so the current in the outside circuit always flows the same way. The output is direct current.

4. A transformer has 500 turns on the primary coil and 100 turns on the secondary coil. The primary potential difference is 240 V. Calculate the secondary potential difference.

Hint

The ratio of the potential differences equals the ratio of the numbers of turns.

Next step

Write Vs=Vp×nsnpV_s = V_p \times \dfrac{n_s}{n_p}, then put in the four numbers.

Full working Vs=Vp×nsnp=240×100500=48 V\begin{aligned} V_s &= V_p \times \frac{n_s}{n_p} \\ &= 240 \times \frac{100}{500} \\ &= 48\,\text{V} \end{aligned}

This is a step-down transformer.

5. A step-up transformer changes 12 V to 240 V. The secondary coil has 2000 turns. Calculate the number of turns on the primary coil.

Hint

You want the primary turns, so rearrange the turns equation first.

Next step

Write np=ns×VpVsn_p = n_s \times \dfrac{V_p}{V_s}, then work out 2000×122402000 \times \dfrac{12}{240}.

Full working np=ns×VpVs=2000×12240=100\begin{aligned} n_p &= n_s \times \frac{V_p}{V_s} \\ &= 2000 \times \frac{12}{240} \\ &= 100 \end{aligned}

6. A transformer has a primary potential difference of 11 000 V and a primary current of 0.50 A. The secondary potential difference is 250 V. Assume the transformer is 100% efficient. Calculate the secondary current.

Hint

If the transformer is 100% efficient, the power input equals the power output.

Next step

Write VsIs=VpIpV_s I_s = V_p I_p, then work out 11 000×0.50250\dfrac{11\,000 \times 0.50}{250}.

Full working VsIs=VpIpIs=VpIpVs=11 000×0.50250=22 A\begin{aligned} V_s I_s &= V_p I_p \\ I_s &= \frac{V_p I_p}{V_s} \\ &= \frac{11\,000 \times 0.50}{250} \\ &= 22\,\text{A} \end{aligned}

7. Explain why a transformer does not work when it is connected to a steady direct current supply.

Hint

A transformer needs a changing magnetic field in its core.

Next step

Say what a steady d.c. does to the field in the core, then say whether a potential difference is induced in the secondary coil.

Full working

A transformer works because the alternating current in the primary coil makes a changing magnetic field in the core. The changing field induces a potential difference in the secondary coil. A steady direct current makes a steady field, so the field in the core does not change and no potential difference is induced.

8. Explain why the national grid transmits electrical power at a very high potential difference.

Hint

Use P=VIP = VI. For the same power, what happens to the current when the potential difference is large?

Next step

Say that the current is smaller, then link a smaller current to less heating in the cables.

Full working

For the same power, a higher potential difference means a smaller current, because P=VIP = VI. A smaller current transfers less energy to the thermal store of the transmission cables, so less energy is wasted as the cables heat up.