Give every answer with its unit, and to the number of significant figures the data justify. Write the turns ratio with the secondary turns on top, and remember that a step-up transformer increases the voltage but leaves the power unchanged.

  1. A transformer has 200 turns on the primary and 800 turns on the secondary. The primary voltage is 12 V. Calculate the secondary voltage.
  2. A transformer has 1000 turns on the primary and 100 turns on the secondary. The primary voltage is 230 V. Calculate the secondary voltage.
  3. A transformer steps a voltage of 240 V down to 12 V. The primary coil has 500 turns. Calculate the number of turns on the secondary coil.
  4. An ideal transformer has a primary voltage of 12 V and a primary current of 2.0 A. The secondary voltage is 48 V. Calculate the secondary current.
  5. A transformer has an input power of 800 W and an output power of 720 W. Calculate its efficiency.
  6. A power station delivers 10 kW along a cable of resistance 5.0 Ω at a voltage of 500 V. Calculate the current in the cable and the power lost in it.
  7. Explain why electrical energy is transmitted along the national grid at a very high voltage.
  8. The chapter problem. The generator delivers 24 kW at an r.m.s. voltage of 240 V, and the transmission cable has a resistance of 4.0 Ω. Calculate the current and the power lost in the cable when the voltage is not raised, and again when a step-up transformer raises it to 24 kV. State the turns ratio of that transformer.

Answers and concise solutions

1. Show the answer

1. Secondary voltage

Answer: Vs=Vp×NsNp=12×800200=12×4=48 VV_s = V_p \times \dfrac{N_s}{N_p} = 12 \times \dfrac{800}{200} = 12 \times 4 = 48\,\text{V}. The secondary has four times as many turns, so it has four times the voltage.

2. Show the answer

2. Secondary voltage

Answer: Vs=Vp×NsNp=230×1001000=230×0.10=23 VV_s = V_p \times \dfrac{N_s}{N_p} = 230 \times \dfrac{100}{1000} = 230 \times 0.10 = 23\,\text{V}. This is a step-down transformer: the secondary has one tenth of the turns, so it has one tenth of the voltage.

3. Show the answer

3. Secondary turns

Answer: Rearranging the transformer equation gives Ns=Np×VsVp=500×12240=500×0.050=25N_s = N_p \times \dfrac{V_s}{V_p} = 500 \times \dfrac{12}{240} = 500 \times 0.050 = 25. The secondary coil has 25 turns, which is one twentieth of the primary turns, so the voltage is one twentieth of 240 V.

4. Show the answer

4. Secondary current

Answer: An ideal transformer transfers all the power, so VpIp=VsIsV_pI_p = V_sI_s and Is=VpIpVs=12×2.048=2448=0.50 AI_s = \dfrac{V_pI_p}{V_s} = \dfrac{12 \times 2.0}{48} = \dfrac{24}{48} = 0.50\,\text{A}. The voltage went up four times and the current went down four times, so the power stays 24 W on both sides.

5. Show the answer

5. Efficiency

Answer: efficiency=power outpower in×100%=720800×100%=90%\text{efficiency} = \dfrac{\text{power out}}{\text{power in}} \times 100\% = \dfrac{720}{800} \times 100\% = 90\%. The other 80 W is transferred to the core and the windings, which warm up.

6. Show the answer

6. Current and power lost

Answer: The current is I=PV=10 000500=20 AI = \dfrac{P}{V} = \dfrac{10\,000}{500} = 20\,\text{A}. The power lost is Plost=I2R=202×5.0=400×5.0=2000 WP_{\text{lost}} = I^2R = 20^2 \times 5.0 = 400 \times 5.0 = 2000\,\text{W}, which is 2.0 kW. Sending the same power at 10 kV would need a current of only 1.0 A and would waste only 5.0 W.

7. Show the answer

7. Why the grid uses a high voltage

Answer: For a given power, a higher voltage means a smaller current, because P=VIP = VI. The power lost in the cable is I2RI^2R, so a smaller current wastes much less energy. Transformers step the voltage up for the journey and down again for the user, and an ideal transformer does not change the power. The high voltage is therefore about reducing the current, not about increasing the energy delivered.

8. Show the answer

8. Currents and power losses

Answer: At 240 V the current is I=PV=24 000240=100 AI = \dfrac{P}{V} = \dfrac{24\,000}{240} = 100\,\text{A}, and the cable wastes Plost=I2R=1002×4.0=40 000 WP_{\text{lost}} = I^2R = 100^2 \times 4.0 = 40\,000\,\text{W}, which is more than the generator supplies. Stepped up to 24 kV the current is I=24 00024 000=1.0 AI = \dfrac{24\,000}{24\,000} = 1.0\,\text{A}, and the waste is 1.02×4.0=4.0 W1.0^2 \times 4.0 = 4.0\,\text{W}. The turns ratio is NsNp=24 000240=100\dfrac{N_s}{N_p} = \dfrac{24\,000}{240} = 100, so a 100-turn primary needs a 10 000-turn secondary.