Leaving Certificate Physics1.2 Measuring, accuracy and uncertainty

All books

1.2 Measuring, accuracy and uncertainty — Learn

Prerequisites: physical quantities, units and significant figures from Section 1.1.

Objectives: choose a suitable instrument; state the reading uncertainty of a single measurement; calculate absolute and percentage uncertainty; combine uncertainties for sums and for products; find the uncertainty in a mean; tell random from systematic error, and precision from accuracy.

By the end of this section, you can put a range on a measurement and say how much the range matters.

Every measurement has a range

No measurement is exact. A metre stick marked in millimetres cannot tell you the length to a millionth of a metre. A stopwatch started by hand cannot tell you the time to a thousandth of a second. The honest way to report a measurement is as a value with an uncertainty:

length=0.250 m±0.001 m\text{length} = 0.250\,\text{m} \pm 0.001\,\text{m}

The ±\pm part is the absolute uncertainty. It says how far the true value could reasonably lie from your reading.

The reading uncertainty

An instrument's smallest division is the gap between two marks on its scale. For an analogue scale, we take the reading uncertainty of a single reading to be half the smallest division.

A metre stick marked in millimetres has a smallest division of 1 mm, so the reading uncertainty is ±0.5 mm=±0.0005 m\pm 0.5\,\text{mm} = \pm 0.0005\,\text{m}.

A digital instrument usually reads to the last digit on its display. Its reading uncertainty is ±1\pm 1 in that last digit.

Absolute and percentage uncertainty

The percentage uncertainty compares the uncertainty with the reading itself.

percentage uncertainty=absolute uncertaintyreading×100%\text{percentage uncertainty} = \frac{\text{absolute uncertainty}}{\text{reading}} \times 100\%

Example 1. An extension is measured as 0.040 m, with a reading uncertainty of ±0.001\pm 0.001 m. Calculate the percentage uncertainty.

percentage uncertainty=0.0010.040×100%=2.5%\text{percentage uncertainty} = \frac{0.001}{0.040} \times 100\% = 2.5\%

Combining uncertainties

When a result is calculated from several measurements, each uncertainty passes into the result. The rule depends on the arithmetic.

Example 2. Two lengths are added: 0.120 m ±\pm 0.001 m and 0.080 m ±\pm 0.001 m. Find the total and its uncertainty.

0.120+0.080=0.200 m0.001+0.001=0.002 m0.120 + 0.080 = 0.200\,\text{m} \qquad 0.001 + 0.001 = 0.002\,\text{m}

The total is 0.200 m±0.002 m0.200\,\text{m} \pm 0.002\,\text{m}.

Example 3. A force of 12.0 N ±\pm 3% moves an object 0.50 m ±\pm 2%. Calculate the work and its uncertainty.

W=Fd=12.0×0.50=6.0 JW = Fd = 12.0 \times 0.50 = 6.0\,\text{J}

where WW is the work, FF the force and dd the distance moved. The percentage uncertainties add: 3%+2%=5%3\% + 2\% = 5\%. That is 0.300.30 J of 6.06.0 J, so

W=6.0 J±0.30 JW = 6.0\,\text{J} \pm 0.30\,\text{J}

The uncertainty in a mean

Repeating a measurement and taking the mean reduces the effect of random error. The spread of the repeats gives the uncertainty.

The simplest rule is half the range: subtract the smallest reading from the largest, then halve the answer.

Example 4. A ball is timed four times: 0.46 s, 0.44 s, 0.48 s and 0.46 s. Find the mean and its uncertainty.

mean=0.46+0.44+0.48+0.464=0.46 s\text{mean} = \frac{0.46 + 0.44 + 0.48 + 0.46}{4} = 0.46\,\text{s} range=0.48−0.44=0.04 suncertainty=0.042=0.02 s\text{range} = 0.48 - 0.44 = 0.04\,\text{s} \qquad \text{uncertainty} = \frac{0.04}{2} = 0.02\,\text{s}

The result is 0.46 s±0.02 s0.46\,\text{s} \pm 0.02\,\text{s}.

Accuracy, precision, random and systematic

Two words describe different things about a set of readings.

Readings can be precise and not accurate. That pattern is the signature of a systematic error, which pushes every reading the same way. A random error scatters the readings above and below the true value, so a mean reduces it.

Progress check

Back to the chapter problem. You are timing a ball as it falls about 1 m.

Write down two sources of uncertainty in your timing, and say whether each is random or systematic. Then estimate the percentage uncertainty in a fall time of 0.45 s if your reaction time is about 0.20 s. Keep the answer: it decides how much of any difference between your measurement and the model is your fault.

You should now be able to