Leaving Certificate Physics16.1 Magnetic flux and flux density

All books

16.1 Magnetic flux and flux density — Learn

Prerequisites: magnetic fields and magnetic flux density from Section 15.1; the area of a rectangle; the tesla as the unit of flux density.

Objectives: define magnetic flux and magnetic flux density; use Φ=BA\Phi = BA; find the flux linkage of a coil.

By the end of this section, you can find how much magnetic field passes through a coil, and how that amount changes when the coil turns.

Two ways to measure a magnetic field

A magnetic field can be described in two ways, and they answer two different questions.

Magnetic flux density, BB, tells you how strong the field is at a point. Its unit is the tesla (T). Chapter 15 used BB to find the force on a current-carrying wire.

Magnetic flux, Φ\Phi (the Greek letter phi), tells you how much field passes through a surface. Its unit is the weber (Wb).

Think of a field as rain falling on a window. The flux density is how heavy the rain is. The flux is how much water passes through the window in total, which depends on the rain and on the size of the window.

Magnetic flux

For a flat surface of area AA placed at right angles to a uniform field of flux density BB, the magnetic flux is

Φ=BA\Phi = BA

Because the unit of flux is the weber and the unit of area is the square metre, the tesla is the same as a weber per square metre:

1 T=1 Wb/m21\,\text{T} = 1\,\text{Wb/m}^2

Example 1. A coil of area 0.040 m² lies at right angles to a field of flux density 0.25 T. Calculate the flux through the coil.

Φ=BA\Phi = BA Φ=0.25×0.040\Phi = 0.25 \times 0.040 Φ=0.010 Wb\Phi = 0.010\,\text{Wb}

Example 2. A field of flux density 0.15 T passes at right angles through a coil of area 0.020 m². Calculate the flux through the coil.

Φ=BA=0.15×0.020=3.0×10−3 Wb\Phi = BA = 0.15 \times 0.020 = 3.0 \times 10^{-3}\,\text{Wb}

Example 3. The flux through a surface of area 0.050 m² is 0.020 Wb. Calculate the flux density of the field.

Rearranging Φ=BA\Phi = BA for BB:

B=ΦA=0.0200.050=0.40 TB = \frac{\Phi}{A} = \frac{0.020}{0.050} = 0.40\,\text{T}

Orientation

The flux through a coil depends on how the coil is turned.

This is the whole reason a generator works. A coil turning in a steady field has a flux through it that rises and falls, and Section 16.2 shows that a changing flux is what drives a current.

Flux linkage

A coil has many turns, and the same flux passes through every one of them. The voltage induced in the coil depends on the total, so it is useful to record the flux through all the turns together. This is the flux linkage:

NΦ=NBAN\Phi = NBA

The weber-turn has the same dimensions as the weber, because NN is a pure number. We write it as Wb and remember that it counts every turn.

Example 4. A coil of 300 turns, each of area 0.020 m², lies at right angles to a field of flux density 0.15 T. Calculate the flux through one turn and the flux linkage of the coil.

The flux through one turn is

Φ=BA=0.15×0.020=3.0×10−3 Wb\Phi = BA = 0.15 \times 0.020 = 3.0 \times 10^{-3}\,\text{Wb}

The flux linkage is

NΦ=300×3.0×10−3=0.90 WbN\Phi = 300 \times 3.0 \times 10^{-3} = 0.90\,\text{Wb}

Progress check

Back to the chapter problem. The generator coil has 180 turns, and each turn encloses an area of 0.020 m². The coil turns in a field of flux density 0.30 T.

Find the flux through one turn when the plane of the coil is at right angles to the field. Then find the flux linkage of the whole coil in that position. Keep both numbers: Section 16.2 uses the flux linkage to find the induced voltage, and the answer depends on how fast that flux linkage changes.

You should now be able to