Leaving Certificate Physics16.1 Magnetic flux and flux density

All books

16.1 Magnetic flux and flux density — Practise with help

Warm-up: remember

  1. A straight wire of length 0.20 m carries a current of 3.0 A at right angles to a magnetic field of flux density 0.15 T. Calculate the force on the wire.
  2. A rectangle is 0.20 m long and 0.10 m wide. Calculate its area in square metres.
Answers and feedback
  1. F=BIL=0.15×3.0×0.20=0.090 NF = BIL = 0.15 \times 3.0 \times 0.20 = 0.090\,\text{N}. The flux density BB is what Chapter 15 used to find a force. In this section the same BB is used to find a flux, which is a different quantity.
  2. A=0.20×0.10=0.020 m2A = 0.20 \times 0.10 = 0.020\,\text{m}^2. Keep the area in square metres. A coil of 200 cm² has an area of 0.020 m², because 1 m2=1×104 cm21\,\text{m}^2 = 1 \times 10^{4}\,\text{cm}^2.

Practise with help

1. A coil of area 0.050 m² lies at right angles to a field of flux density 0.20 T. Calculate the flux through the coil.

Hint

You are given BB and AA, and asked for Φ\Phi. Use Φ=BA\Phi = BA.

Next step

Φ=0.20×0.050\Phi = 0.20 \times 0.050.

Full working Φ=BA=0.20×0.050=0.010 Wb\Phi = BA = 0.20 \times 0.050 = 0.010\,\text{Wb}

The unit works out too: T×m2=Wb\text{T} \times \text{m}^2 = \text{Wb}.

2. The flux through a surface of area 0.080 m² is 0.024 Wb. Calculate the flux density of the field.

Hint

Rearrange Φ=BA\Phi = BA for BB.

Next step

B=ΦA=0.0240.080B = \dfrac{\Phi}{A} = \dfrac{0.024}{0.080}.

Full working B=ΦA=0.0240.080=0.30 TB = \frac{\Phi}{A} = \frac{0.024}{0.080} = 0.30\,\text{T}

Check the sense of it: a flux of 0.024 Wb spread over 0.080 m² is 0.30 Wb in each square metre, so the flux density is 0.30 T.

3. A coil of 150 turns, each of area 0.040 m², lies at right angles to a field of flux density 0.25 T. Calculate the flux through one turn and the flux linkage of the coil.

Hint

Find the flux through one turn first, then multiply by the number of turns.

Next step

Φ=0.25×0.040=0.010\Phi = 0.25 \times 0.040 = 0.010 Wb, then NΦ=150×0.010N\Phi = 150 \times 0.010.

Full working Φ=BA=0.25×0.040=0.010 Wb\Phi = BA = 0.25 \times 0.040 = 0.010\,\text{Wb} NΦ=150×0.010=1.5 WbN\Phi = 150 \times 0.010 = 1.5\,\text{Wb}

The flux linkage is 150 times larger than the flux through one turn, because the same field passes through all 150 turns.

4. A coil of 250 turns has a flux of 4.0×10−34.0 \times 10^{-3} Wb through each turn. Calculate the flux linkage of the coil.

Hint

You are given NN and Φ\Phi, and asked for NΦN\Phi.

Next step

NΦ=250×4.0×10−3N\Phi = 250 \times 4.0 \times 10^{-3}.

Full working NΦ=250×4.0×10−3=1.0 WbN\Phi = 250 \times 4.0 \times 10^{-3} = 1.0\,\text{Wb}

The flux linkage is the quantity that Faraday's law uses, so it is worth finding before Section 16.2 begins.

5. A coil is turned from a position where its plane is at right angles to the field to a position where its plane is parallel to the field. Describe what happens to the flux through the coil, and state its value in the second position.

Hint

At right angles, the field passes straight through the coil. What happens when the field runs along the coil instead?

Next step

The flux starts at its largest value, BABA, and falls as the coil turns.

Full working

In the first position the plane of the coil is at right angles to the field, so the flux has its largest value, Φ=BA\Phi = BA. As the coil turns, less of the field passes through it, so the flux falls steadily. In the second position the field runs along the plane of the coil, so no field passes through it and the flux is zero.

This change is the reason a generator works. A coil turning steadily in a constant field has a flux that rises and falls, and it is the change that drives the current.

6. A field of flux density 0.45 T passes through a coil of area 0.020 m². The coil is turned so that the plane is no longer at right angles to the field. Explain why the flux through the coil is now smaller than 9.0 mWb.

Hint

The formula Φ=BA\Phi = BA gives the largest possible value, for one particular orientation.

Next step

Turning the coil changes how much of the field passes through it.

Full working

At right angles, the flux is Φ=BA=0.45×0.020=9.0×10−3\Phi = BA = 0.45 \times 0.020 = 9.0 \times 10^{-3} Wb, which is 9.0 mWb. That is the largest value the flux can have for this coil in this field.

When the coil turns away from that position, the field meets the coil at an angle and less of it passes through. The flux therefore falls below 9.0 mWb. It reaches zero when the plane of the coil is parallel to the field.

A question from Chapter 14

7. A resistor of resistance 15 Ω has a potential difference of 6.0 V across it. Calculate the current through it.

Hint

Use Ohm's law, V=IRV = IR.

Next step

I=VR=6.015I = \dfrac{V}{R} = \dfrac{6.0}{15}.

Full working I=VR=6.015=0.40 AI = \frac{V}{R} = \frac{6.0}{15} = 0.40\,\text{A}

This matters here because an induced voltage drives a current through the resistance of the coil and the circuit. Once you have the induced voltage, Ohm's law gives the current.

Settings

Colour scheme

Light or dark pages. Your colour and layout stay the same.

Colour

The paper, ink and lettering. Your layout stays the same.

Quiet colours
Bold colours
Layout

How pages are arranged. Your colours stay the same.

Reading offline

Keep this book on this device and read it offline.