Leaving Certificate Physics16.5 Transformers and the transmission of electricity

All books

16.5 Transformers and the transmission of electricity — Learn

Prerequisites: Faraday's law from Section 16.2; Lenz's law from Section 16.3; the a.c. generator from Section 16.4; power and resistance from Chapter 14.

Objectives: describe the structure of a transformer; use VsVp=NsNp\dfrac{V_s}{V_p} = \dfrac{N_s}{N_p}; use the efficiency of a transformer; explain why electricity is transmitted at a high voltage and calculate the energy lost in a cable.

By the end of this section, you can choose the turns of a transformer for a job, and show why the national grid uses a very high voltage.

Mutual induction

A transformer changes the size of an alternating voltage. It has two coils wound on a closed iron core.

An alternating current in the primary makes a changing magnetic flux in the core. That changing flux passes through the secondary coil, and Faraday's law says a changing flux induces an emf. So an emf appears in the secondary. This is mutual induction: a changing field in one coil induces an emf in the other.

A transformer works only on an alternating supply. A steady direct current makes a steady flux, and a steady flux induces nothing.

The transformer equation

The emf induced in a coil is proportional to the number of turns, so the voltages are in the same ratio as the turns:

VsVp=NsNp\frac{V_s}{V_p} = \frac{N_s}{N_p}

A step-up transformer has more turns on the secondary, so VsV_s is larger than VpV_p. A step-down transformer has fewer turns on the secondary, so VsV_s is smaller than VpV_p.

Power and efficiency

An ideal transformer transfers all the power from the primary to the secondary, so

VpIp=VsIsV_p I_p = V_s I_s

where IpI_p is the current in the primary coil and IsI_s is the current in the secondary coil.

If the voltage is stepped up, the current is stepped down by the same factor. The turns ratio and the current ratio are opposite ways round:

IpIs=NsNp\frac{I_p}{I_s} = \frac{N_s}{N_p}

A real transformer transfers a little less power than it receives, because energy is transferred to the core and to the windings. Its efficiency is

efficiency=power outpower in×100%\text{efficiency} = \frac{\text{power out}}{\text{power in}} \times 100\%

Example 1. A transformer has 100 turns on the primary and 10 000 turns on the secondary. The primary voltage is 240 V. Calculate the secondary voltage.

VsVp=NsNp\frac{V_s}{V_p} = \frac{N_s}{N_p} Vs=Vp×NsNp=240×10 000100=240×100V_s = V_p \times \frac{N_s}{N_p} = 240 \times \frac{10\,000}{100} = 240 \times 100 Vs=24 000 VV_s = 24\,000\,\text{V}

That is 24 kV, so this is a step-up transformer.

Example 2. The transformer of Example 1 delivers a power of 24 kW. Calculate the current in the secondary coil.

Is=PVs=24 00024 000=1.0 AI_s = \frac{P}{V_s} = \frac{24\,000}{24\,000} = 1.0\,\text{A}

Example 3. A transformer has an input power of 500 W and an output power of 475 W. Calculate its efficiency.

efficiency=475500×100%=95%\text{efficiency} = \frac{475}{500} \times 100\% = 95\%
Figure 1

Predict, then test. Before you move any slider, write down what you expect the secondary voltage to be if you double the number of secondary turns. Then double it and check. Now change the primary voltage and describe how the secondary voltage changes. Write a sentence explaining why the ratio of the voltages is fixed by the turns.

Why the grid uses a high voltage

A power station delivers energy to a city along a cable. The cable has resistance, so some of the energy is transferred to the cable and wasted as internal energy. The wasted power is

Plost=I2RP_{\text{lost}} = I^2R

The resistance RR is fixed by the cable. So the way to reduce the waste is to reduce the current II. For a given power PP, the current is

I=PVI = \frac{P}{V}

so a higher voltage means a smaller current. Because the loss depends on I2I^2, halving the current cuts the waste to one quarter.

That is why the grid steps the voltage up for the journey and steps it down again at the far end. The transformers do not reduce the energy transferred. They change the voltage and the current in opposite directions, so the power stays the same and less energy is wasted.

Progress check

Back to the chapter problem. The generator delivers 24 kW at an r.m.s. voltage of 240 V. The transmission cable has a resistance of 4.0 Ω.

Find the current that would flow in the cable if the voltage were not raised, and the power lost in the cable. Then find the current when the voltage is stepped up to 24 kV, and the power lost then. Compare the two answers, and explain why the grid uses a high voltage.

You should now be able to